In addition to responding to SNMP GET and SNMP SET requests, the SNMP subagent generates
TRAPs. While one component of the SNMP subagent waits for SNMP requests from the SNMP
Master Agent, another component of the SNMP subagent monitors the System Event Log (SEL).
Entries are placed in the SEL when significant events occur on the server, such as when a
temperature sensor’s reading exceeds a threshold, or when a power supply is removed. When a
new SEL entry is detected, the SNMP subagent analyzes the SEL entry and sends SNMP TRAPs to
the SNMP Master Agent. The SNMP Master Agent duplicates and transmits the SNMP TRAP to
all nodes that are configured to receive traps from the managed server. You must configure trap
recipients as part of installing and configuring the SNMP Master Agent.
The SNMP subagent uses a Platform Management Abstraction Layer (PMAL) and the IPMI driver
to access the information from the BMC, such as information about power supplies, voltages,
temperature sensors, cooling devices, chassis intrusion sensors, and the SEL. The information
regarding processors and memory are stored in the SMBIOS tables and are accessed through either
the IPMI driver or through direct memory mapping.
Features of the Baseboard SNMP Subagent
Through basic SNMP GETs, SETs, and TRAPs, the SNMP subagent provides the following
functionality for managing servers:
Accessing sensor data
Viewing and modifying threshold settings
Reading the SMBIOS tables
Providing overall system health status
Accessing Sensor Data
The SNMP subagent accesses management information through IPMI commands that the BMC on
the managed server responds to. The information available varies by platform. For example, some
servers don’t support chassis intrusion detection, and some don’t support server monitoring of
redundant fans, although individual fans are monitored. The SNMP subagent’s Management
Information Base (MIB) is designed to support the following list of components:
Voltage
Temperature
System Fan (includes redundancy)
Memory
Processor
Power Supply (includes redundancy)
PCI Hot Plug Events
Chassis
Events are generated by the SNMP agent based on SEL events and provide as much information as
possible concerning the event to the event reader. The events use the NOTIFICATION-TYPE
construct specified in SNMPv2C.
Installing and Configuring the Intel
®
Server Manager 8 SNMP Subagents 15